Orthopedics > OCOSH Classification > Trauma > Fractures > Femur Fractures > Periprosthetic Fractures > Young age and wedge stem design are risk factors for periprosthetic fracture after arthroplasty due to hip fracture
Young age and wedge stem design are risk factors for periprosthetic fracture after arthroplasty due to hip fracture
Visit Resource Review It Rate It Bookmark It
Location: http://www.informaworld.com/smpp/section?content=a713723151&fulltext=713240928
Patients and methods We compared 16 patients with late periprosthetic fracture of the femur to 48 controls. The primary diagnosis for all patients was hip fracture. The date of operation for hip fracture was used to select the control group of patients, all of whom were operated at the same time and in the same hospital district. No other selection criteria were used. Complications at the time of index operation, type of prosthesis, age, sex, BMI, patient's diseases, medication, and surgeon's experience were compared using conditional logistic regression.
Results We found that low age at the time of the hip fracture operation increased the risk of periprosthetic fracture (OR = 4.9, CI = 1.2-20). The polished wedge type of prosthesis was associated with a higher risk of periprosthetic fracture than were other designs (OR = 11, CI = 1.2-97).
Interpretation These findings of risk factors for peri-prosthetic fracture are new and should be confirmed by further studies using larger numbers of patients.
Type: Reference Material
Author/Contact: Sarvilinna et al
Institution: Acta Orthopaedica
Primary Subject/Category:
Submitted by: admin
Hits: 886
Added: Thu Oct 04 2007
Previous