Hip Replacement Arthroplasty (Subscribe) XML icon Add to My Yahoo!  Add to Google

Internet resources relating to Hip Replacement Arthroplasty
[OCOSH Code: D019644 397956004 OP_AP_R_H]

 Advanced Search

Categories

Hip Hemireplacement (6)
Resources relating to hip hemireplacement arthroplasty
MeSH Search Term "Arthroplasty, Replacement, Hip"[mesh]
ICD-10 Code n/a
SNOMED-CT Term Partial hip replacement by prosthesis (procedure) Concept ID: 386649003
Synonyms - Prosthetic hemiarthroplasty of the hip
OCOSH Code: D019644 386649003 OP_AP_R_H_HM
Hip Resurfacing Arthroplasty (5)
Internet resources relating to Hip Resurfacing Arthroplasty
MeSH Search Term "Arthroplasty, Replacement, Hip"[mesh]
ICD-10 Code n/a
SNOMED-CT Term Primary resurfacing arthroplasty of joint (procedure) Concept ID: 179547003
OCOSH Code: D019644 179547003 OP_AP_R_H_RS
Revision Hip Replacement (17)
Internet resources relating to Revision Hip Replacement
MeSH Search Term "Arthroplasty, Replacement, Hip"[mesh]
ICD-10 Code n/a
SNOMED-CT Term Revision of hip arthroplasty (procedure) Concept ID: 280460009
OCOSH Code: D019644 280460009 OP_AP_R_H_RV

Resources

Pages: 1 2 3 4 5 > >|

Orthopaedic Scores popular

Location: http://www.orthopaedicscores.com

Goldmine of orthopaedic scores and scoring systems. 10 surgeon based and 20 patient based scoring systems for all regions of the musculoskeletal system. Includes: Harris Hip Score, Knee Society Score, Oxford Knee Score, WOMAC, Cincinatti Knee Score, Tegner Lysholm, American Foot & Ankle Score AFAS, UCLA Shoulder Rating Scale, Mayo...
[Categories]

View Details Visit Resource Read 1 Review Review It Rate It Bookmark It Added: Thu Nov 09 2006

1997 First experience with omnifit hip prosthesis with hydroxyapatite

Location: http://www.rz.uni-duesseldorf.de/WWW/MedFak/Orthopaedie/journal/issue1-97/txis197_1.htm

First experience with omnifit hip prosthesis with hydroxyapatite: minimum two years follow-up
A.Carfagni, R .Giacomi, C.F.De Biase Internet Journal of Orthopedic Surgery and related Subjects Issue 1 1997 C.F.De Biase Department of Orthopaedic and Traumatology San Carlo di Nancy Roma
The purpose of this study is to evaluate the results obtained by our group fare capo...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Sun Jul 29 2007

2000 Reconstruction of the Pelvis Using a Segmental Autograft of the Ipsilateral Femur

Location: http://www.maitrise-orthop.com/corpusmaitri/orthopaedic/97/puget/pugetus.shtml

Reconstruction of the Pelvis Using a Segmental Autograft of the Ipsilateral Femur
J. Puget
Tumours of the pelvis are doubly difficult to manage: not only does the growth have to be removed, but means have to be devised to guard against postoperative loss of function if the tumour site has involved the...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Tue Nov 02 2010

2009 Posterior femoroacetabular impingement PFAI - after hip resurfacing arthroplasty

Location: http://www.ncbi.nlm.nih.gov/pubmed/19583549

The current study asks the questions, "Does femoroacetabular impingement occur after hip resurfacing arthroplasty (HRA) and, if so, what are the clinical outcomes?"
CONCLUSIONS: Small, corticated, non-progressive erosions can occur from femoroacetabular impingement following HRA. The erosions were more commonly posterior in this series, and they tended to occur in active...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Wed Oct 14 2009

2010 Cemented hip designs are a reasonable option in young patients CORR Open Access

Location: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2974862

Results Eight hips (of 69) were revised (three for infection and five for aseptic loosening) and one hip dislocated for which open reduction was necessary. One additional cup was considered a radiographic failure. The 10-year survival was 83% (95% confidence interval, 69%–92%) with revision for any reason as the end point...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Mon Apr 18 2011

2010 Factors that predict short-term complication rates after total hip arthroplasty CORR Open Access

Location: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2914297

Results Compared with patients treated at high-volume hospitals (above the 20th percentile), patients treated at low-volume hospitals (below the 60th percentile) had a higher aggregate risk of having short-term complications (odds ratio, 2.00). A variety of patient factors also had associations with an increased risk of complications: increased Charlson comorbidity score,...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Mon Apr 18 2011

2010 High long-term survival of bulk femoral head autograft for acetabular reconstruction in cementless THA for developmental hip dysplasia CORR Open Access

Location: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2865593

Conclusions Cementless THA combined with autologous femoral bone graft in patients with developmental dysplasia resulted in a high rate of survival. Structural bone grafting achieved a stable construct until osseointegration occurred. We believe the radiodense bands represent a radiographic sign of successful completion of repair of the deficient acetabulum. Congruous and...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Mon Apr 18 2011

2010 Histological features of pseudotumor-like tissues from metal-on-metal hips CORR Open Access

Location: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2914255

Conclusions Pseudotumor-like reactions can be caused by high wear, but may also occur around implants with low wear, likely because of a metal hypersensitivity reaction. Histologic features including synovial integrity, inflammatory cell infiltrates, tissue organization, and metal particles may help differentiate these causes.
Clinical Relevance Painful hips with periprosthetic masses may be caused...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Mon Apr 18 2011

2010 Risk of complication and revision total hip arthroplasty among Medicare patients with different bearing surfaces CORR Open Access

Location: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2914292

Questions/purposes We compared the short-term risk of complication and revision THA among Medicare patients having a primary THA with metal-polyethylene (M-PE), metal-metal (M-M), and ceramic-ceramic (C-C) bearings.
Conclusions The risk of short-term complication (including dislocation) and revision THA were similar among appropriately matched Medicare THA patients regardless of bearing surface. Hard-on-hard THA bearings...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Tue Apr 19 2011

2011 Is the Internal Rotation Lag Sign a Sensitive Test for Detecting Hip Abductor Tendon Ruptures after Total Hip Arthroplasty Open Access

Location: http://www.pssjournal.com/content/5/1/7/abstract

Results We evaluated this test in 20 patients clinically and by magnetic resonance imaging (MRI). All patients demonstrated a positive internal rotation lag sign. Twelve of them lag of internal rotation and evidence of anterior abductor tendon rupture on MRI, 8 with lag of internal rotation and no evidence of abductor...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Wed Apr 20 2011

2011 Minimally invasive versus classic procedures in total hip arthroplasty CORR Open Access

Location: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3008875

Conclusions The minimal invasive approach in THA did not show a clinically relevant superior outcome in the first postoperative year.
Minimally invasive versus classic procedures in total hip arthroplasty: a double-blind randomized controlled trial. Goosen JH, Kollen BJ, Castelein RM, Kuipers BM, Verheyen CC. Clin Orthop Relat Res. 2011 Jan;469(1):200-8. (full text)
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Mon Apr 18 2011

2011 Wear versus thickness and other features of 5-Mrad crosslinked UHMWPE acetabular liners CORR Open Access

Location: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3018202

Conclusions The reduction in wear with 5 Mrad of crosslinking was not offset by increasing the diameter from 28 mm to 36 mm or by using a liner as thin as 3 mm.
Clinical Relevance The results indicate, for a properly positioned 5-Mrad crosslinked acetabular component and within the range of dimensions evaluated,...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Mon Apr 18 2011

Acetabular wear in Total Hip Arthroplasty eMedicine Orthopedics

Location: http://emedicine.medscape.com/article/1247594-overview

Bezwada, Nazarian & Booth 2004 Updated: Apr 15, 2009
Since the introduction of the low-friction total hip arthroplasty (THA) by Sir John Charnley, wear has been a primary issue in hip arthroplasty. Charnley's original choice for bearing surfaces was a stainless steel head on polytetrafluoroethylene (PTFE). This choice was complicated by...
[Categories]

View Details Visit Resource Review It Rate It Bookmark It Added: Wed Mar 19 2008

Pages: 1 2 3 4 5 > >|